Control of solids

Membrane level indicators

CD ES

Intended use:

Special sensitive membrane level indicator. Is to be used to control the maximum level of bulk solids in silos or vessels or control the flow and obstructions in tubes, pipes, conveyors, etc. With a high sensitivity, the indicator can detect false signals due to vibration or movements of the place where it is mounted.

These controllers consist of a switch actuated by a membrane and it is recommended for dusty and powdery, granulated and grainy bulk goods like dust, flour, grain, sand, plastic, etc. with an easy flow and a bulk density from 0.3 to 2.5 t/m3


Function:

The membrane must to be exposed to the material.

The movement of the switch is the result of the pressure exerted by the incoming bulk material against the membrane which forces the membrane to move backwards, reversing the position of the switch and the signal is used for example to control the transport system in the silo.

The models “A-100”, “AD”, “SR” y “CD2M” and the models with S.S. membrane have a regulation system by a spring that allows the adjustment of the sensitivity. Tightening the regulation nut to reduce the sensitivity and increase the strain of the material to activate the microswitch. Clockwise insensitive.

The models are adjusted at their maximum sensitivity. It is necessary to ensure the proper pressure to the membrane that returns the membrane when there is no product covering it. 

Mechanical connection:

Drill holes in the silo or vessel and mount the indicator using screws, rods, fasteners or nuts M6 making sure of the easy flow of the material and ensure that the product leaves the membrane without product on it.

Dimensions:

Approximate measures are given in mm. 

 

 

 

Technical data:

Name Membrane level indicator  
Type CD ES ref: 2203...
Density of the product 0.3 t/m3 ... 2.5 t/m3  
Ambient pressure Atmospherical  
Maximum pressure +0.5 bar  
Cable entry M20x1.5  
Maximum voltage 250 V AC  
Contact function 1 NO + 1 NC  
Capacity of the contact 5 A / 250 V AC
(for resistive loads)
For inductive or capacitive loads
 
Ambient temperature:    
CD standard -20 ºC ... +60 ºC  
CD with Aluminium housing -25 ºC ... +80 ºC  
Protection: According DIN EN60529  
CD standard IP53 / IP40 depending on the position of the cable gland  
CD with Aluminium housing IP65  
Weight:    
CD standard 0.48 kg  
CD with Aluminium housing 0.95 kg  
Sensitivity 60 ... 1000 g
(Depending of the model. Consult your application to our Technical Department)
 
Materials:    
Housing Glass reinforced Polyester
(Under request Aluminium)
 
Membrane NBR
(Under request Viton)
 
Mounting ring and screws Zincated Steel
(Under request Stainless Steel 1.4301)