111

Control of liquids

Float levels switch

TM S-60

Intended use:

The floats are to be used to control the level in the filling and emptying processes of tanks, wells and containers in which aggressive liquids, like acids, alkaloids and a wide range of chemical products or hydrocarbons are used. 


Function:

When the level of the liquid reaches the level of the float switch, the float changes its position an angle and the Reed contact open or close the electric circuit due to this deviation.
It is necessary to install 2 devices to control of the maximum and the minimum levels automatically. 

Mechanical connection:

It is simple: the switch literally hangs on its own cable at the desired height and is fixed to the ceiling or to one side of the tank adjusting the distance of the counterweight, if it was requested. 

Dimensions:

Approximate measures are given in mm. 

 

 

 

Technical data:

Name Float switch    
Type TM S-60 ...    
Density of the product 0.75 kg/l    
Maximum pressure +1 bar    
Switching voltage 24 ... 250 V AC/DC    
Power consumption 60 VA in AC; 60 W in DC    
Contact function 1 NO + 1 NC    
Capacity of the contact 1 mA ... 1 A
(for resistive loads)
For inductive or capacitive loads, reduce at 50%
   
Ambient temperature 0 °C ... +150 °C    
Protection IP6X according DIN EN60529    
Float weight 0.22 kg    
Cable length 05 5 meter cable ref: 2504-2-05E  
  10 10 m cable ref: 2504-2-10E  
  20 20 m cable ref: 2504-2-20E  
Materials:      
Float PTFE    
Cable Double isolation PTFE    
Counterweight PTFE